High accuracy determinations of 2 e/h using the ac Josephson effect require correspondingly accurate measurements of small dc voltages. In the preliminary stages of a determination of Z e/h with substantially improved accuracy, two different potentiometric instruments based on two independent principles of operation were designed and built. Both instruments were used in an extended series of 2 e/h measurements at the University of Pennsylvania and subsequently at the National Bureau of Standards where they have been used to realize the U. S. legal volt as recently redefined via the ac Josephson effect. One of these instruments is based on a modified senes-parallel technique and is described in detail in this paper. After treating the general theory of the low resistance case, the design and construction of a portable self-checking instrument based on the double series-parallel exchange method is described. This series-parallel comparator (SPC), built to compare a Josephson device (10 mV) and a standard cell (1 V), was evaluated and tested in the course of determinations of 2 e/h with one standard deviation (1 sigma ) uncertainties of about O.1 ppm. The sources of systematic uncertainty are discussed. The uncertainty attributable to the comparator alone is about 3 parts in 10/sup 8/(1 sigma ). (auth)

Research Organization:
Department of Physics and Laboratory for Research on the Structure of Matter, University of Pennsylvania, Philadelphia, Pennsylvania 19174
Sponsoring Organization:
USDOE
NSA Number:
NSA-29-001576
OSTI ID:
4388488
Journal Information:
Rev. Sci. Instrum., v. 44, no. 8, pp. 944-953, Journal Name: Rev. Sci. Instrum., v. 44, no. 8, pp. 944-953; ISSN RSINA
Country of Publication:
United States
Language:
English

Similar Records

Accuracy of measurements of the quantized Hall resistivity by a direct current comparator type potentiometer; Calibration using a Josephson potentiometer
Journal Article · Fri Mar 31 23:00:00 EST 1989 · IEEE (Institute of Electrical and Electronics Engineers) Transactions on Instrumentation and Measurement; (USA) · OSTI ID:5147527

Realization of a primary voltage standard based on the Josephson effect
Technical Report · Sun Jun 01 00:00:00 EDT 1975 · OSTI ID:5170864

Prototype for a commercial Josephson-effect voltage standard
Conference · Sat Dec 31 23:00:00 EST 1977 · AIP Conf. Proc.; (United States) · OSTI ID:5256315