Period detection instrument for nuclear reactor safety systems
Journal Article
·
· Nucl. Instrum. Methods, v. 113, no. 2, pp. 207-216
A reactor-peried detection instrument featuring a high degree of freedom from scrams due to spurious signals has been designed, constructed, and tested. The technique employed is suitable for critical facilities and power reactors. Voltage level changes V(t) from a logarithmic amplifier are utilized to determine reactor period when signal levels are small, and both voltage level changes V(t) and the rate-of-change of voltage level dV(t)/dt are utilized when signal currents are large. Due to the low noise level of this hybrid circuit, the overall response speed of the log N amplifier and the dV(t)/dt period circuit can be significantly improved while greatly decreasing the chance of noise-induced scrams. (auth)
- Research Organization:
- Argonne National Lab., IL
- Sponsoring Organization:
- USDOE
- NSA Number:
- NSA-29-012972
- OSTI ID:
- 4385823
- Journal Information:
- Nucl. Instrum. Methods, v. 113, no. 2, pp. 207-216, Journal Name: Nucl. Instrum. Methods, v. 113, no. 2, pp. 207-216; ISSN NUIMA
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
The Log Count Rate Period Meter Used with Safety Circuits
The Log Count Rate Period Meter Used with Safety Circuits
Period meter for reactors
Journal Article
·
Sat Jul 01 00:00:00 EDT 1961
· IRE Transactions on Nuclear Science
·
OSTI ID:4006412
The Log Count Rate Period Meter Used with Safety Circuits
Journal Article
·
Sat Dec 31 23:00:00 EST 1960
· IRE Intern. Conv. Record
·
OSTI ID:4802830
Period meter for reactors
Patent
·
Mon Jan 05 23:00:00 EST 1976
·
OSTI ID:862441