Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Construction and Operation of the AE-6 Water Boiler Reactor

Technical Report ·
DOI:https://doi.org/10.2172/4365867· OSTI ID:4365867
The AE-6 Reactor has been constructed and tested for use in the power range 0 to 2 kw. This reactor is a modification of the Water Boiler Neutron Source formerly located at the Downey Plant of North American Aviation, Inc. The chief modifications, which were made to permit higher power operation, were the addition of a vapor pressure type gas recombiner and a cooling system. Changes which were made in the reactor are described and the procedure for the critical loading of the reactor is given. Many of the operating characteristics of the reactor have been experimentally determined and are herein presented. Copies of the operating rules and start-up procedure are also included.
Research Organization:
North American Aviation, Inc., Canoga Park, CA (United States). Atomics International Div.
Sponsoring Organization:
US Atomic Energy Commission (AEC); USDOE National Nuclear Security Administration (NNSA), Nuclear Criticality Safety Program (NCSP)
DOE Contract Number:
AT-11-1-GEN-8
NSA Number:
NSA-11-011422
OSTI ID:
4365867
Report Number(s):
NAA-SR--1920
Country of Publication:
United States
Language:
English