High-accuracy, two-dimensional read-out in multiwire proportional chambers
Journal Article
·
· Nucl. Instrum. Methods, v. 113, no. 3, pp. 381-385
By measuring the center of gravity of the pulses induced on cathode strips in a multiwire proportional chamber it is shown that a good two-dimensional accuracy can be reached, of the order of 150 μm. Applications for two-dimensional read-out in drift chambers or low energy X-ray mapping are discussed.
- Research Organization:
- European Organization for Nuclear Research, Geneva
- NSA Number:
- NSA-29-010183
- OSTI ID:
- 4364786
- Journal Information:
- Nucl. Instrum. Methods, v. 113, no. 3, pp. 381-385, Journal Name: Nucl. Instrum. Methods, v. 113, no. 3, pp. 381-385; ISSN NUIMA
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
New particle detectors: The multiwire proportional chamber and the drift chamber
Calibration of cathode strip gains in multiwire drift chambers of the GlueX experiment
Distribution of cathode charge in a multiwire proportional chamber