MEASUREMENT OF THE FAST-NEUTRON SPECTRUM OF THE BULK SHIELDING REACTOR USING NUCLEAR PLATES

Technical Report ·
OSTI ID:4355497
BS>A nuclear plate camera was developed at the Bulk Shielding Facility to measure the fast-neutron spectrum of the reactor. A proton-recoil type fast- neutron spectrometer was used to measure the reactor spectra as attenuated by the BeO reflector and various amounts of H/sub 2/O. Since data can be obtained much more quickly with the spectrometer, no extensive use of nuclear plates is contemplated. However, the nuclear plate method is of established reliability, and it was considered desirable to check the spectrometer at at lease one point. It was found that the total integrated flux as measured by the two method differs by approximately 11.3%, which is within the statistical accuracy of the two instruments. (auth)
Research Organization:
Oak Ridge National Lab., Tenn.
DOE Contract Number:
W-7405-ENG-26
NSA Number:
NSA-12-000997
OSTI ID:
4355497
Report Number(s):
CF-53-8-146
Country of Publication:
United States
Language:
English

Similar Records

Neutron Flux Spectrum Studies in the PCTR Fast Neutron Cavity
Technical Report · Fri Oct 31 23:00:00 EST 1969 · OSTI ID:1988753

SHIELD FOR NEUTRON PROBE
Patent · Mon Oct 30 23:00:00 EST 1961 · OSTI ID:4074107

Fast-neutron spectrum measurement by a stilbene scintillaion spectrometer
Journal Article · Mon Dec 31 23:00:00 EST 1973 · Czech. J. Phys., v. 24, no. 1, pp. 48-54 · OSTI ID:4332389