Zinc wired rebar
Journal Article
·
· Materials Performance
OSTI ID:435343
- COMINCO Product Technology Centre, Mississauga, Ontario (Canada)
A novel method for corrosion protection of rebar in concrete is reported wherein it is galvanically protected by attaching a zinc wire along its length. The self-corrosion and galvanic-corrosion loss of the zinc wire is dependent on the water/cement ratio, the size of the cathode, and the concrete cover thickness. The wire acts as a sacrificial anode when the rebar embedded in concrete is exposed to corrosive environments.
- OSTI ID:
- 435343
- Journal Information:
- Materials Performance, Journal Name: Materials Performance Journal Issue: 2 Vol. 36; ISSN 0094-1492; ISSN MTPFBI
- Country of Publication:
- United States
- Language:
- English