PERFORMANCE OF THE HOFFMAN CYCLONE
Performance tests were conducted on a cyclone collector developed and manufactured by the U S. Hoffman Company to determine whether it had any special advantages for precleaning feed materials gas streams prior to bag filtration. Weight collection efficiency and resistance were determined at flow rates ranging from 50 to 185 cu. ft per min. for atmospheric dust copper sulfate microspheres talc and resuspended fly ash. Dust concentrations varied from 0.05 grain per 1000 cu. ft (atmospheric dust) to 31 grains per cu ft (fly ash). Fly ash collection was investigated as a function of gas temperature 70 to 700 deg , and inlet loading 0.1 to 31 grains per cu. ft. Test results indicated that special design features of this unit did not materially increase the collection efficiency above that of simple cyclones. Furthermore, the resistance at rated flow was considerably higher than that for other collectors
- Research Organization:
- Harvard Univ., Boston. Air Cleaning Lab.
- NSA Number:
- NSA-12-007788
- OSTI ID:
- 4352431
- Report Number(s):
- NYO-4613
- Country of Publication:
- United States
- Language:
- English
Similar Records
Process to eliminate production of fly ash by wet bottom boilers
Performance of an aerodynamic particle separator
LABORATORY PERFORMANCE OF THE MIKRO-PULSAIRE COLLECTOR (MODEL J-9-6A)
Patent
·
Tue Sep 03 00:00:00 EDT 1991
·
OSTI ID:5804164
Performance of an aerodynamic particle separator
Journal Article
·
Mon Dec 30 23:00:00 EST 1996
· Waste Management
·
OSTI ID:566319
LABORATORY PERFORMANCE OF THE MIKRO-PULSAIRE COLLECTOR (MODEL J-9-6A)
Technical Report
·
Fri Jun 15 00:00:00 EDT 1962
·
OSTI ID:4737932