A DETERMINATION OF THE GAMMA-RAY EMISSION OF RADIUM

Journal Article · · J. Research Natl. Bur. Standards
DOI:https://doi.org/10.6028/jres.059.034· OSTI ID:4348489
Measurements of the gamma -ray emission of radium (roentgens per milligram-hour at 1 centimeter) have been made by means of a graphite cavity ionization chamber. An auxiliary experimental examination of the stopping-power correction for the non-air-equivalence of the cavity wall is also described. The resulting average value for the gamma -ray emission of radium (enclosed in an 0.5-millimeter platinum capsule) is 8.26 plus or minus 0.05 roentgens per milligram-hour at 1 centimeter, which is based upon the conclusion that the stopping-power data of Bakker and Segre are consistent with the results of the auxiliary experiment. (auth)
Research Organization:
Originating Research Org. not identified
Sponsoring Organization:
USDOE
NSA Number:
NSA-12-001769
OSTI ID:
4348489
Journal Information:
J. Research Natl. Bur. Standards, Journal Name: J. Research Natl. Bur. Standards Vol. Vol: 59
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

MEASUREMENT OF THE GAMMA CONSTANT OF RADIUM
Journal Article · Wed Nov 30 23:00:00 EST 1960 · Izmeritel'naya Tekh. · OSTI ID:4074761

AUGER AND CONVERSION SPECTRUM OF RADIUM D (thesis)
Technical Report · Sun Jun 01 00:00:00 EDT 1958 · OSTI ID:4796490

Mound Laboratory participation in the Kelley-Koett Instrument Company radium accident
Technical Report · Wed Sep 19 00:00:00 EDT 1951 · OSTI ID:495712