Title: S3G/S4G PRELIMINARY DESIGN DESCRIPTION EMERGENCY PRESSURIZING SYSTEM

Technical Report ·
OSTI ID:4346921

The emergency pressurizing system is designed to maintain cooling system pressure during periods in which pressurized coolant demands exceed the capacity of ihe pressurizer. The system consists of a bank of high pressure water fiasks and the necessary piping and valves for pressurizing the flasks with air and injecting the water into the charging system. Flasks may be refilled by forcing water through charging system piping or by loading charging water storage tanks with low pressure air. Resign specifications and drawings and performance characteristics are given. (D.E.B.)

Research Organization:
Knolls Atomic Power Lab., Schenectady, N.Y.
DOE Contract Number:
W-31-109-ENG-52
NSA Number:
NSA-12-002108
OSTI ID:
4346921
Report Number(s):
KAPL-M-SSD-21
Resource Relation:
Other Information: 1 illus. Orig. Receipt Date: 31-DEC-58
Country of Publication:
United States
Language:
English

Similar Records

S3G/S4G REACTOR SERVICE AIR SYSTEM DESIGN DESCRIPTION
Technical Report · Tue May 01 00:00:00 EDT 1956 · OSTI ID:4346921

COO S3G/S4G COOLANT CHARGING SYSTEM DESIGN DESCRIPTION
Technical Report · Wed Oct 31 00:00:00 EST 1956 · OSTI ID:4346921

S3G/S4G CORROSION INHIBITING SYSTEM DESIGN DESCRIPTION
Technical Report · Mon Mar 12 00:00:00 EST 1956 · OSTI ID:4346921