Optimization of multistage harmonic gyrodevices
- Institute for Plasma Research, University of Maryland, College Park, Maryland 20742 (United States)
- Naval Research Laboratory, Washington, D.C. 20375 (United States)
- Helsinki University of Technology, Helsinki (Finland)
In low voltage gyrodevices operating at high cyclotron harmonics the electrons are weakly coupled to the synchronous harmonic of an electromagnetic field. To realize efficient operation of a device it is necessary to compensate for this weak coupling by increasing the resonator {ital Q}-factor. When the required {ital Q}-factor is on the order of the Ohmic {ital Q}-factor, the optimization of gyrotron parameters should be modified by taking into account Ohmic losses of the microwave power. In the present paper this modification has been done and the optimization of two- and three-cavity gyrodevices operating at cyclotron harmonics has been considered. {copyright} {ital 1996 American Institute of Physics.}
- OSTI ID:
- 434669
- Journal Information:
- Physics of Plasmas, Journal Name: Physics of Plasmas Journal Issue: 8 Vol. 3; ISSN PHPAEN; ISSN 1070-664X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Optimization of multistage harmonic gyrodevices
Two-harmonic prebunching of electrons in multicavity gyrodevices
High-harmonic gyrotron with sectioned cavity
Conference
·
Mon Dec 30 23:00:00 EST 1996
·
OSTI ID:435467
Two-harmonic prebunching of electrons in multicavity gyrodevices
Journal Article
·
Tue Jan 31 23:00:00 EST 1995
· Physics of Plasmas
·
OSTI ID:165988
High-harmonic gyrotron with sectioned cavity
Journal Article
·
Thu Jul 15 00:00:00 EDT 2010
· Physics of Plasmas
·
OSTI ID:21389130