FACTORS INFLUENCING THE SELECTION AND PERFORMANCE OF THE DEAERATING FEED LINE DEMINERALIZER RESIN
Technical Report
·
OSTI ID:4345228
To prevent the entry of Ar and O/sub 2/ into the main coolant system, an adjunct to the S3G/S4G Main Coolant Charging System has been designed to permit the use of deaerated condensate from the secondary system for filling and make-up to the main coolant system. A deaerating feed tank in the secondary system will provide the means of deaeration. The deaerated condensate from the DFT is tapped from the discharge of the feed booster pump at a pressure of 80 psia, is cooled and then purified by passage through a small demineraiizer, which is located in the deaerated feed charging line downstream of the DFT. This report discusses the service conditions under which the demineralizer will operate and the expected performance of the ion exchnnge resin under these conditions. (auth)
- Research Organization:
- Knolls Atomic Power Lab., Schenectady, N.Y.
- DOE Contract Number:
- W-31-109-ENG-52
- NSA Number:
- NSA-12-002511
- OSTI ID:
- 4345228
- Report Number(s):
- KAPL-M-SMS-42 and Suppl.
- Country of Publication:
- United States
- Language:
- English
Similar Records
TRANSIENT PERFORMANCE ANALYSIS OF THE S3G/S4G DEAERATING FEED TANK
S3G CORROSION PRODUCT ACTIVITY BUILDUP WITH A STAINLESS STEEL UNIT CELL
S3G/S4G HIGH TEMPERATURE PURIFICATION WITH AN AXIAL BED FILTER
Technical Report
·
Thu May 01 00:00:00 EDT 1958
·
OSTI ID:4340496
S3G CORROSION PRODUCT ACTIVITY BUILDUP WITH A STAINLESS STEEL UNIT CELL
Technical Report
·
Mon Sep 30 00:00:00 EDT 1957
·
OSTI ID:4342721
S3G/S4G HIGH TEMPERATURE PURIFICATION WITH AN AXIAL BED FILTER
Technical Report
·
Tue Dec 31 23:00:00 EST 1957
·
OSTI ID:4340451