Calorimetric measurements of the losses of a superconducting coil wound from a moderately twisted multifilamentary superconducting wire have been made with a coil current consisting of a direct current and a superimposed ac component at frequencies between 1 and 100 Hz. There exists a frequency range where the loss per cycle decreases with increasing frequency. Magnetization measurements on a sample of the multifilament wire in an applied inductance B = B/ sub s/ + B/sub o/ sin omega t confirmed the results of the calorimetric measurements and indicated that with increasing frequency the flow of magnetic flux into and out of the composite during a cycle becomes more and more diminished. (auth)
- Research Organization:
- Eidgenoessische Technische Hochschule, Zurich
- NSA Number:
- NSA-29-022828
- OSTI ID:
- 4343778
- Journal Information:
- Cryogenics, v. 14, no. 2, pp. 71-76, Journal Name: Cryogenics, v. 14, no. 2, pp. 71-76; ISSN CRYOA
- Country of Publication:
- United Kingdom
- Language:
- English
Similar Records
Reduction of the ac losses of multifilament superconductors by the use of low twist rates
Ac losses of multifilament superconductors at frequencies between 1 and 500 Hz
ac losses of superconducting solenoidal coils
Journal Article
·
Sun Oct 31 23:00:00 EST 1976
· J. Appl. Phys.; (United States)
·
OSTI ID:7347356
Ac losses of multifilament superconductors at frequencies between 1 and 500 Hz
Conference
·
Sat Mar 01 00:00:00 EDT 1975
· IEEE Trans. Magn., v. MAG-11, no. 2, pp. 321-323
·
OSTI ID:4095013
ac losses of superconducting solenoidal coils
Journal Article
·
Thu Dec 31 23:00:00 EST 1981
· J. Appl. Phys.; (United States)
·
OSTI ID:5825815