Reciprocating compressor valve failure -- Digital modelling and analysis
Conference
·
OSTI ID:434111
- NOVA Gas Transmission Ltd., Calgary, Alberta (Canada)
Many problems in reciprocating compressors are caused by valve failures. Usually, valve failures are diagnosed early, and the worn out parts are replaced. This requires, however, unscheduled compressor shutdowns which increase the cost of operation and possibly breach gas delivery contracts. Thus, it is essential to design valves adequate for the particular compressors and flow conditions. In this paper, it is determined that the cause of an unusually large number of valve failures at one of the NOVA Gas Transmission Limited (NGTL) compressor stations was an inadequate valve design. It is shown that the type of valve presently used is unacceptable and should be replaced. Due to economic restrictions, however, the existing valves are modified rather than replaced. The method used to re-design the compressor valves includes two steps: field measurements and computer digital modelling. The modelling incorporates: (1) acoustic simulation of the system, (2) compressor valve dynamic simulation, and (3) simultaneous simulation of fluid solid interactions between the compressor valves, compressor cylinders and pipework. The results obtained by using models of (2) and (3) are compared.
- OSTI ID:
- 434111
- Report Number(s):
- CONF-9606127--; ISBN 0-7918-1767-9
- Country of Publication:
- United States
- Language:
- English
Similar Records
Experiences with simulation of reciprocating compressor valve dynamics
Increase reliability of reciprocating hydrogen compressors
Valve stiction in reciprocating compressors
Conference
·
Mon Dec 30 23:00:00 EST 1996
·
OSTI ID:434108
Increase reliability of reciprocating hydrogen compressors
Journal Article
·
Sun Dec 31 23:00:00 EST 1995
· Hydrocarbon Processing
·
OSTI ID:178356
Valve stiction in reciprocating compressors
Book
·
Mon Dec 30 23:00:00 EST 1996
·
OSTI ID:483926