Details of the stress analysis performed on the tubes, tubesheet and divider plate components of current Westinghouse steam generators when subjected to combined Loss-of-Coolant-Accident ( LOCA) and Safe Shutdown Earthquake (SSE) loads are presented. The analysis indicates that the stresses in the components studied are within ASME Boiler and Pressure Vessel Code, Section III allowable limits. (auth)