DETERMINATION OF MERCURY IN SOLIDS FROM S3G/S4G MAIN COOLANT PUMP
Technical Report
·
OSTI ID:4335616
The distillation-amalgamation method for mercury in ores was applied with slight modifications to the determination of mercury in solid material (crud) removed from S3G/S4G coolant pumps. The sample of crud is dried at 50 to 75 deg C, cooled, weighed, and transferred to a VYCOR cruclble. The crucible is covered with a weighed gdid foil which is cooled by contact with a beaker of ice. Heat is applied to the crucible, and mercury is volatilized and condensed on the gold foil. The amalgamated gold foil is reweighed to determine the mercury content of the sample. (auth)
- Research Organization:
- Knolls Atomic Power Lab., Schenectady, N.Y.
- DOE Contract Number:
- W-31-109-ENG-52
- NSA Number:
- NSA-12-010392
- OSTI ID:
- 4335616
- Report Number(s):
- KAPL-M-VFC-2
- Country of Publication:
- United States
- Language:
- English
Similar Records
DOSE RATES ON THE S3G/S4G BOILER AND PRIMARY COOLANT PIPING AFTER SHUTDOWN
S3G/S4G HIGH TEMPERATURE PURIFICATION WITH AN AXIAL BED FILTER
TRANSIENT PERFORMANCE ANALYSIS OF THE S3G/S4G DEAERATING FEED TANK
Technical Report
·
Mon Feb 17 23:00:00 EST 1958
·
OSTI ID:4310487
S3G/S4G HIGH TEMPERATURE PURIFICATION WITH AN AXIAL BED FILTER
Technical Report
·
Tue Dec 31 23:00:00 EST 1957
·
OSTI ID:4340451
TRANSIENT PERFORMANCE ANALYSIS OF THE S3G/S4G DEAERATING FEED TANK
Technical Report
·
Thu May 01 00:00:00 EDT 1958
·
OSTI ID:4340496