Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

COULOMETRIC TITRATIONS IN MOLTEN LITHIUM CHLORIDE-POTASSIUM CHLORIDE EUTECTIC. Technical Report No. 4

Technical Report ·
OSTI ID:4335614

Electrolytically generated iron (III) was used as an oxidant in coulometric titrations in molten lithium chloride--potassium chioride at 460 deg C to titrate chromium (II) to chromium (III) and vanadium (II) to vanadium (III). The potentiometric amperometric with one electrode, and the dead-stop methods of end point detection are compared. Apparatus and procedures are described, and various schemes are evaluated. (J.R.D.)

Research Organization:
Illinois. Univ., Urbana
NSA Number:
NSA-12-010394
OSTI ID:
4335614
Report Number(s):
NP-6730
Country of Publication:
United States
Language:
English