BI-METALLIC TUBE STEAM GENERATOR FOR APPR-1. VOLUME I. SPECIFICATIONS
These three volumes were issued separately, but are cataloged as a unit. Complete specifications and drawings are given for a bi-metallic tube steam generator replacement at Fort Belvoir, Virginia. Physical size limitations, shell side water volume, limitation, type of exchanger, materials of construction, conditions of service, required performance, and weight limitation are included. Procedures are outlined for removing the existing steam generator at APPR-1 and installing a new unit. The effect of replacing the present Type 304 stainless steel boiler with a bi-metallic tube steam generator was analyzed from the standpoint of chemical operations at the plant. Corrosion control procedures were established to prevent formation of deposits, scale, or pits on the boiler tubes as well as to protect other parts of the system. Water treatment procedures were revised to insure satisfactory operation of the boiler by removing dissolved oxygen, minimizing hideout and carryover, neutraliziog carbon dioxide, and maintaining proper pH. The chemical feed system was revised to eliminate problems encountered with the present equipment and to obtain the reliability required with a less corrosion resistant boiler material. Operating; procedures were reviewed to reflect the above and to switch emphasis from chloride to oxygen control in the make-up, storage, and condensate systems. (auth)
- Research Organization:
- Alco Products, Inc., Schenectady, N.Y.
- Sponsoring Organization:
- US Atomic Energy Commission (AEC)
- NSA Number:
- NSA-12-012695
- OSTI ID:
- 4335131
- Report Number(s):
- APAE-34(Vol.I)
- Country of Publication:
- United States
- Language:
- English
Similar Records
Bi-Metallic Tube Steam Generator for APPR-1. Volume II. Installation Procedures
Bi-Metallic Tube Steam Generator for Appr-1. Volume III. Chemical Technology Design Analysis
APPR-1 BURNOUT CALCULATIONS
Technical Report
·
Wed Jun 25 00:00:00 EDT 1958
·
OSTI ID:1129033
Bi-Metallic Tube Steam Generator for Appr-1. Volume III. Chemical Technology Design Analysis
Technical Report
·
Wed Jun 25 00:00:00 EDT 1958
·
OSTI ID:1129036
APPR-1 BURNOUT CALCULATIONS
Technical Report
·
Wed Apr 09 23:00:00 EST 1958
·
OSTI ID:4165220
Related Subjects
ACIDITY
BOILING
CARBON DIOXIDE
CHEMICAL REACTIONS
CHLORIDES
CONTAMINATION
COOLANT LOOPS
CORROSION
CORROSION PROTECTION
DIAGRAMS
GENERATORS
HEAT EXCHANGERS
IMPURITIES
ION EXCHANGE
MAINTENANCE
MECHANICAL STRUCTURES
OXYGEN
PHYSICS
PLANNING
POWER PLANTS
REMOTE CONTROL
REPROCESSING
SM-1
STAINLESS STEELS
STEAM
STORAGE
TUBES
WATER
WATER COOLANT
WEIGHT
BOILING
CARBON DIOXIDE
CHEMICAL REACTIONS
CHLORIDES
CONTAMINATION
COOLANT LOOPS
CORROSION
CORROSION PROTECTION
DIAGRAMS
GENERATORS
HEAT EXCHANGERS
IMPURITIES
ION EXCHANGE
MAINTENANCE
MECHANICAL STRUCTURES
OXYGEN
PHYSICS
PLANNING
POWER PLANTS
REMOTE CONTROL
REPROCESSING
SM-1
STAINLESS STEELS
STEAM
STORAGE
TUBES
WATER
WATER COOLANT
WEIGHT