DEVELOPMENT OF A METHOD FOR PREDICTING CONTINUOUS TRICKLE-TYPE COLUMN DISSOLVER BEHAVIOR FROM BATCH DATA
A method for determining dissolver solution concentration as a function of length of column traversed for trickletype continuous dissolvers has been developed. An illustrative example is worked out for the mercury-catalyzed nitric acid dissolution of U-Al cast alloy slugs. The method employs a graphical integration of simple functions of dissolution rates and acid concentrations. These rates and concentrations are easily obtained from batch experiments made over the important ranges of concentration. (auth)
- Research Organization:
- Oak Ridge National Lab., Tenn.
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- W-7405-ENG-26
- NSA Number:
- NSA-12-000893
- OSTI ID:
- 4332635
- Report Number(s):
- CF-54-5-74
- Country of Publication:
- United States
- Language:
- English