Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

IMPROVED PULSED SOLVENT EXTRACTION COLUMN CARTRIDGE

Technical Report ·
OSTI ID:4328410
It has been demonstrated that imporved efficiencies and/or throughputs can be obtained in pulse columns if deviations from equally-spaced, identical stainless steel sieve plates are incorporated into the design of the column internals. Some of the techniques found advantageous in uranium tributyl phosphate in diluent systems include the utilization of: nozzle plates, sieve plates of different geometry and spacing, and sieve plates fabricated from different materials of construction Test results are delineated and compared with those from other studies. The influence of plate geometry on the effects produced by mixing metal and plastic sieve plates is discussed. ( auth)
Research Organization:
General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
NSA Number:
NSA-12-014683
OSTI ID:
4328410
Report Number(s):
A/CONF.15/P/515
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

ORGANIC CONTINUOUS CARTRIDGE FOR THE PUREX 2D COLUMN
Technical Report · Thu Aug 16 00:00:00 EDT 1956 · OSTI ID:4153952

Multiphase Large Eddy Simulation of a Pulsed Sieve-Plate Extraction Column - 18125
Conference · Sun Jul 01 00:00:00 EDT 2018 · OSTI ID:22975320

LONGITUDINAL MIXING IN A PULSED SIEVE-PLATE EXTRACTION COLUMN
Journal Article · Tue Sep 01 00:00:00 EDT 1959 · Industrial and Engineering Chemistry (U.S.) Formerly J. Ind. Eng. Chem. Superseded by Chem. Technol. · OSTI ID:4215703