Investigation of the performance of a cold trap for sodium impurities (in Russian)

Journal Article · · At. Energ. (USSR), v. 35, no. 6, pp. 396-400
OSTI ID:4327798
Test results of an air-cooled cold trap for sodium impurities are presented. The relative distribution in height of sodium oxide as it accumulates was measured by teans of gamma-ray radioscopy. The dependence of heat transfer coefficients on the flow rates of air and sodium and the quantity of accumulated oxides was found. Coefficients of oxygen retention in the trap were determined. (auth)
Research Organization:
Originating Research Org. not identified
NSA Number:
NSA-29-020796
OSTI ID:
4327798
Journal Information:
At. Energ. (USSR), v. 35, no. 6, pp. 396-400, Journal Name: At. Energ. (USSR), v. 35, no. 6, pp. 396-400; ISSN AENGA
Country of Publication:
Country unknown/Code not available
Language:
Russian

Similar Records

Computer analysis of sodium cold trap design and performance. [LMFBR]
Conference · Mon Oct 31 23:00:00 EST 1983 · OSTI ID:5281916

Forced-circulation cold trap assembly for removal of sodium impurities
Technical Report · Wed Dec 31 23:00:00 EST 1975 · OSTI ID:4091917

Design criteria and candidate concept for high-performance cold trap
Technical Report · Sun Dec 31 23:00:00 EST 1978 · OSTI ID:6348391