PWR FLOW COASTDOWN CURVES FOR SIMULTANEOUS LOSS OF ALL FOUR OR ALL THREE PUMPS

Technical Report ·
OSTI ID:4327660

Flow coastdown curves are given for the Shippingport Pressurized Water Reactor Plant (PWR) with core 1 installed at four loop and three loop oopration under assumption of simultaneous power loss to all pumps operating. The calculation of the flow coastdown curves was carried out only for a 16-second time interval. It is expected that flow will continue after 15 seconds, with the chock valve hung open. Natural convective circulation will maintain some flow as a result of decay heat from the core, when the flow coastdowm rate approaches that consistent with the thermal driving head. (W.L.H.)

Research Organization:
Westinghouse Electric Corp. Bettis Plant, Pittsburgh
NSA Number:
NSA-12-007484
OSTI ID:
4327660
Report Number(s):
WAPD-PWR-PA-2025
Country of Publication:
United States
Language:
English

Similar Records

FLOW COASTDOWN TEST OF THE PWR MAIN COOLANT PUMP
Technical Report · Thu Aug 30 00:00:00 EDT 1956 · OSTI ID:4353598

PRIMARY COOLANT FLOW COASTDOWN IN PWR CORE 1. Test Evaluation
Technical Report · Fri Mar 31 23:00:00 EST 1961 · OSTI ID:4715826

Analysis of VTR Primary Pump Coastdown
Technical Report · Fri Apr 26 00:00:00 EDT 2019 · OSTI ID:1868341