DETERMINATION OF PROMPT NEUTRON DECAY CONSTANTS OF MULTIPLYING SYSTEMS
Technical Report
·
OSTI ID:4325760
In a multiplying system below prompt critical, the noutron population in the absence of delayed prompt neutron precursors would decay as e/sup -at/ after a normal mode was established, where a is thae prompt neutron decay constant. This constant was measured by three different techniques: the pulsed neutron method, the Rossi alpha method, and a related method originally devised by Feyman to measure the mean square number of neutrons emitted per thermal fission. (M.H.R.)
- Research Organization:
- California. Univ., Livermore. Radiation Lab.; Knolls Atomic Power Lab., Schenectady, N.Y.; Michigan. Univ., Ann Arbor; Argonne National Lab., Lemont, Ill.
- Sponsoring Organization:
- USDOE
- NSA Number:
- NSA-12-015074
- OSTI ID:
- 4325760
- Report Number(s):
- A/CONF.15/P/1783; UCRL-5159(Re
- Country of Publication:
- United States
- Language:
- English