INVESTIGATION OF PULSE CHANNEL OPERATION WITH A FISSION COUNTER IN HIGH GAMMA RADIATION
Technical Report
·
OSTI ID:4324418
Tests were conducted to determine the performance of a fission counter detector and the associated pulse amplifier chain when the counter is subjected to an intense gamma flux. The fission counter filling gas was 99% angon + 1% nitrogen at 1 atm. pressure instead of the original filling of 2 atm. of nitrogen. The results of the tests indicate that a 50% reduction in over-all gain and a minor change in the preamp input circuit were necessary, and in the presence of about 10/sup 5/ r/hr gamma flux, the sensitivity of the system is reduced by 20%. This sensitivity is defined as the number of neutron counts for a given flux with the background counting rate set at 10 cps. (auth)
- Research Organization:
- Westinghouse Electric Corp. Bettis Plant, Pittsburgh
- NSA Number:
- NSA-12-002418
- OSTI ID:
- 4324418
- Report Number(s):
- WAPD-EM-177(Rev.)
- Resource Relation:
- Other Information: Orig. Receipt Date: 31-DEC-58
- Country of Publication:
- United States
- Language:
- English
Similar Records
Design of optimized RC-CR filters for current-pulse operation of fission counters and high sensitivity fission counters for high gamma backgrounds
Design of optimized RC-CR filters for current-pulse operation of fission counters and high sensitivity fission counters for high gamma backgrounds
Ultra high-sensitivity fission counter with transmission line electrode configuration
Conference
·
Wed Jan 01 00:00:00 EST 1975
·
OSTI ID:4324418
Design of optimized RC-CR filters for current-pulse operation of fission counters and high sensitivity fission counters for high gamma backgrounds
Conference
·
Sun Feb 01 00:00:00 EST 1976
· IEEE Trans. Nucl. Sci., v. NS-23, no. 1, pp. 331-341
·
OSTI ID:4324418
Ultra high-sensitivity fission counter with transmission line electrode configuration
Journal Article
·
Tue Feb 01 00:00:00 EST 1983
· IEEE Trans. Nucl. Sci.; (United States)
·
OSTI ID:4324418
+4 more