ADDITIONAL BURNOUT DATA FOR A RECTANGULAR CHANNEL HAVING A COSINE AXIAL HEAT FLUX DISTRIBUTION
Technical Report
·
OSTI ID:4313688
Single channel and parallel channel burnout data were obtained at 2000 psia for 0.057 in. x 2.116 in. x 27 in. long and 0.055 in. x 2.116 in. x 27 in. long machined stainless steel rectangular channels in the vertical position. These channels had a cosine axial heat flux distribution. Previous data for a cosine heated channel are also included. The results indicate that the burnout heat flux in a rectangular channel having a cosine axial flux distribution may be predicted by the method presented in WAPD-SFR-Rs-444. There is no significant effect on burnout heat flux due to an unheated parallel channel. (auth)
- Research Organization:
- Westinghouse Electric Corp. Bettis Plant, Pittsburgh
- NSA Number:
- NSA-12-004155
- OSTI ID:
- 4313688
- Report Number(s):
- WAPD-TH-227
- Country of Publication:
- United States
- Language:
- English
Similar Records
HIGH HEAT FLUX TESTS AND BURNOUT TEST ON PARALLEL FLOW RODS
PRELIMINARY INVESTIGATION OF BURNOUT AND PRESSURE DROP AT 830 AND 1215 PSIA WITH A PARALLEL CHANNEL EFFECT
UPFLOW BURNOUT DATA FOR WATER IN RECTANGULAR CHANNELS AT PRESSURES FROM 600 TO 1870 PSIA
Technical Report
·
Thu Oct 31 23:00:00 EST 1957
·
OSTI ID:4299916
PRELIMINARY INVESTIGATION OF BURNOUT AND PRESSURE DROP AT 830 AND 1215 PSIA WITH A PARALLEL CHANNEL EFFECT
Technical Report
·
Sat Jul 28 00:00:00 EDT 1956
·
OSTI ID:4343777
UPFLOW BURNOUT DATA FOR WATER IN RECTANGULAR CHANNELS AT PRESSURES FROM 600 TO 1870 PSIA
Technical Report
·
Sun Sep 01 00:00:00 EDT 1957
·
OSTI ID:4341046