ADDITIONAL BURNOUT DATA FOR A RECTANGULAR CHANNEL HAVING A COSINE AXIAL HEAT FLUX DISTRIBUTION

Technical Report ·
OSTI ID:4313688
Single channel and parallel channel burnout data were obtained at 2000 psia for 0.057 in. x 2.116 in. x 27 in. long and 0.055 in. x 2.116 in. x 27 in. long machined stainless steel rectangular channels in the vertical position. These channels had a cosine axial heat flux distribution. Previous data for a cosine heated channel are also included. The results indicate that the burnout heat flux in a rectangular channel having a cosine axial flux distribution may be predicted by the method presented in WAPD-SFR-Rs-444. There is no significant effect on burnout heat flux due to an unheated parallel channel. (auth)
Research Organization:
Westinghouse Electric Corp. Bettis Plant, Pittsburgh
NSA Number:
NSA-12-004155
OSTI ID:
4313688
Report Number(s):
WAPD-TH-227
Country of Publication:
United States