CORRELATION OF CAVITATION INCEPTION DATA FOR A CENTRIFUGAL PUMP OPERATING IN WATER AND IN SODIUM POTASSIUM ALLOY (NaK)
For the centrifugal pump under investigation, the static head at pump suction, in feet absolute, at cavitation inception was correlated for water and for 1500 F NaK on the basis of the differences of the vapor pressures of the two liquids. The difference between the vapor pressure of water and NaK, for the same conditions of pump speed and liquid flow, was added to the water-test cavitation inception value, and this estimate proved to be a good approximation to the experimental value found for cavitation inception with NaK. (auth)