THE DETERMINATION OF URANIUM AS AN IMPURITY IN ZIRCONIUM AND ZIRCALOY

Technical Report ·
OSTI ID:4311186
The determination of uranium in zirconium and Zircaloy in the range O.25to 20 ppm on a one gram sample basis. These limits can be varied by changing the size aliquot used for the final uranium determination. Samples are dissolved in hydrofluoric acid and water. Sulfuric acid is added, and the solutions are taken to dryness. The sulfates are dissolved in hot water and the solutions made 2.3 M in nitric acid and saturated in aluminum nitrate. Uranium is then extracted with diethyl ether. After removing the ether, an aliquot is fused with a button of sodium fluoride. The fluorescence produced by the uranium is measured with a photoelectric fluorometer. (auth)
Research Organization:
Westinghouse Electric Corp. Bettis Plant, Pittsburgh
NSA Number:
NSA-12-013745
OSTI ID:
4311186
Report Number(s):
WAPD-CTA(GLA)-431
Country of Publication:
United States
Language:
English