SAR MAIN COOLANT CHECK VALVE TESTS IN TF-17

Technical Report ·
OSTI ID:4303835
The purpose of TF-17 is to investigate the nature of repetitive slamming of S3G check valves as may be induced in the S3G main coolant piping system, to test methods of prevention of sustained slamming and to evaluate the check valve seat damage caused by slamming. Results of these tests are summarized. (W.L.H.)
Research Organization:
Knolls Atomic Power Lab., Schenectady, N.Y.