Title: Ash chemistry and sintering

Journal Article · · Preprints of Papers, American Chemical Society, Division of Fuel Chemistry
OSTI ID:430298

The thermal behavior of a fuel ash is one important factor to consider when fireside slagging and fouling problems in steam boilers are addressed. It is well known that different types of chemical reactions and melts in deposits play an important role in the build-up of problematic fireside deposits. Low viscous melts occur in steam boilers mainly when salt mixtures are present in the ash. Such are Merent mixtures of alkali and earth alkali sulfates, chlorides and carbonates. These mixtures do not melt at a certain temperature but form a melt in a temperature range which in some cases may be several hundreds of degrees. The amount of melt is crucial for the deposit build-up. For some boilers it has been found that roughly 10 - 20 weight-% melt in an ash mixture would be enough to cause extensive deposit formation, while 60 - 80 weight-% melt would already cause the ash to be so wet it would flow down a vertical tube and not cause any further deposit growth.

OSTI ID:
430298
Report Number(s):
CONF-960376-; ISSN 0569-3772; TRN: 97:000004-0026
Journal Information:
Preprints of Papers, American Chemical Society, Division of Fuel Chemistry, Vol. 41, Issue 2; Conference: Spring national meeting of the American Chemical Society (ACS), New Orleans, LA (United States), 24-28 Mar 1996; Other Information: PBD: 1996
Country of Publication:
United States
Language:
English