Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

IEMP cable coupling phenomenology in small enclosures

Conference · · IEEE (Inst. Elec. Electron. Eng.), Trans. Nucl. Sci., v. NS-20, no. 6, pp. 31-39
OSTI ID:4298278
Experiments were performed to measure IEMP coupling to cables in small cavities for non-space-charge limited conditions. The experiments were designed to separate the magnetic field, electric field, and charge deposition coupling modes. Investigations were made of the efiects of cavity pressure, cable bias potential, and cable type and termination. A theoretical model was developed which represents the various coupling modes by voltage and current sources in a lumped-parameter equivalent circuit. Theoretical predictions were compared to the experimental data. For the configurations investigated the predictions agree with the data to within the experimental uncertainty. (auth)
Research Organization:
General Electric Co., Philadelphia
NSA Number:
NSA-29-029569
OSTI ID:
4298278
Conference Information:
Journal Name: IEEE (Inst. Elec. Electron. Eng.), Trans. Nucl. Sci., v. NS-20, no. 6, pp. 31-39
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

The limits to hardening electronic boxes to IEMP coupling
Journal Article · Tue Nov 30 23:00:00 EST 1982 · IEEE Trans. Nucl. Sci.; (United States) · OSTI ID:5925016

Application of method of characteristics to IEMP cable response
Conference · Sun Nov 30 23:00:00 EST 1975 · IEEE Trans. Nucl. Sci., v. NS-22, no. 6, pp. 2408-2412 · OSTI ID:4071464

Methodology for assessing cable current from IEMP in SREMP environments
Journal Article · Tue Nov 30 23:00:00 EST 1982 · IEEE Trans. Nucl. Sci.; (United States) · OSTI ID:6089221