HRT STEAM SYSTEM FEEDWATER PRESSURE CONTROL
                            Technical Report
                            ·
                            
                            
                            
                    
                                
                                OSTI ID:4297379
                                
                            
                        A frequency response analysis in which system response to sinusoidal perturbations is considered and theorems permit conclusions regarding stability and transient response has been made for the Homogeneous Reactor Test steam system feedwater pressure control system. The analysis indicates that thin system will operate satisfactorily at 1000 psi with controller settings as follows: sensitivity --~4 psi per inch; reset rate -~5 repeats per minute. (auth)