Some criteria are established for the choice of the collimators for a crystal spectrometer for neutron diffraction in order to achieve a good compromise between luminosity and resolution. General expressions for the full width at half maximum and for the luminosity of the diffraction peaks are developed for powder sample. The advantage of the parallel arrangement is also computed. (auth)