Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

REACTOR COOLANT LOOP OUTAGE TEST. SECTION I. SECOND PERFORMANCE. Test Results DL-S-170 (T-554928-A)

Technical Report ·
OSTI ID:4291232
A test was conducted to determine the temperature transient experienced as a result of the loss of an operating loop during power operation, when the main coolant hydraulic stop valves remain open. The temperature transients in the affected loop had no effect on operation of the remaining portions of the plant. In addition, the adequacy of the procedure for removing a loop from service when the reactor is critical was demonstrated. (J.R.D.)
Research Organization:
Duquesne Light Co., Shippingport, Penna.
NSA Number:
NSA-13-009405
OSTI ID:
4291232
Report Number(s):
AECU-4003
Country of Publication:
Country unknown/Code not available
Language:
English