REACTOR COOLANT LOOP OUTAGE TEST. SECTION I. SECOND PERFORMANCE. Test Results DL-S-170 (T-554928-A)
Technical Report
·
OSTI ID:4291232
A test was conducted to determine the temperature transient experienced as a result of the loss of an operating loop during power operation, when the main coolant hydraulic stop valves remain open. The temperature transients in the affected loop had no effect on operation of the remaining portions of the plant. In addition, the adequacy of the procedure for removing a loop from service when the reactor is critical was demonstrated. (J.R.D.)
- Research Organization:
- Duquesne Light Co., Shippingport, Penna.
- NSA Number:
- NSA-13-009405
- OSTI ID:
- 4291232
- Report Number(s):
- AECU-4003
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
MAIN HYDRAULIC VALVE THERMAL SHOCK TEST. Test Evaluation DL-S-188 (T- 612108)
MANUALLY OPERATED REACTOR COOLANT LOOP STOP VALVE TEST. Test Evaluation DLCS 39501
VALVE OPERATING SYSTEM DRIFT TEST. Test Evaluation DL-S-200 (T-641109). Period II
Technical Report
·
Sun Feb 23 23:00:00 EST 1958
·
OSTI ID:4282073
MANUALLY OPERATED REACTOR COOLANT LOOP STOP VALVE TEST. Test Evaluation DLCS 39501
Technical Report
·
Thu May 31 00:00:00 EDT 1962
·
OSTI ID:4786968
VALVE OPERATING SYSTEM DRIFT TEST. Test Evaluation DL-S-200 (T-641109). Period II
Technical Report
·
Fri Oct 17 00:00:00 EDT 1958
·
OSTI ID:4247624