Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

F0020-AN IBM-704 THERMAL TRANSIENT ANALYSIS CODE

Technical Report ·
DOI:https://doi.org/10.2172/4284751· OSTI ID:4284751
An IBM-704 thermal transient analysis code, designated F0020 was developed to reduce transient test data for a single vertical, rectangular coolant channel. Modes of heat transfer to water at 2000 psia covered by this code include forced convection (turbulent flow), nucleate boiling, departure from nucleate boiling, partial film boiling, and film boiling. The code will accommodate a plate mesh, and associated heat generation weighting factors, of a maximum of 50 axial and 10 radial nodes. (auth)
Research Organization:
Westinghouse Electric Corp. Bettis Plant, Pittsburgh
DOE Contract Number:
AT(11-1)-GEN-14
NSA Number:
NSA-13-010379
OSTI ID:
4284751
Report Number(s):
WAPD-TM-145
Country of Publication:
United States
Language:
English