Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

SOME OPERATION EXPERIENCE WITH THE SWISS POOL-TYPE REACTOR SAPHIR

Technical Report ·
OSTI ID:4283594

An account is given of the major changes on the swimming pool reactor operated by the USAEC at the first Geneva Conference now operating at Wurenlingen. The calibration of the control rods and the measurement of their release time are described. Several critical arrangements are shown. The flux distribution and power calibration are given. The temperature, power, and xenon effects are discussed. The influence of beam holes on reactivity is shown. The results are given for several methods of determining the pool water activity. The decay of N/ sup 156/ in the hold-up tank was measured. (W.D.M.)

Research Organization:
Reactor Ltd., Wurenlingen, Switzerland
NSA Number:
NSA-13-007105
OSTI ID:
4283594
Report Number(s):
A/CONF.15/P/260
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

DESCRIPTION OF THE SWISS RESEARCH REACTORS
Technical Report · Mon Aug 12 00:00:00 EDT 1957 · OSTI ID:4356967

SOME ASPECTS OF THE DESIGN OF RESEARCH REACTORS OF THE "SWIMMING POOL TYPE"
Journal Article · Mon Feb 29 23:00:00 EST 1960 · Bol. inform. junta control energia atomica (Peru) · OSTI ID:4180992

DESCRIPTION OF ORNL POOL TYPE CRITICAL FACILITY
Technical Report · Tue Jul 16 00:00:00 EDT 1957 · OSTI ID:4208976