INVESTIGATION OF HASTINGS FLOWMETER FOR MEASURING THE FLOW RATE OF URANIUM HEXAFLUORIDE
Technical Report
·
OSTI ID:4282343
A Hastings flowmeter was investigated for use in metering the flow of uranium hexafluoride gas. This type of flowmeter gave evidence that tt could successfully measure the flow of UF/sub 6/; however, certain changes would have to be made in the standard instrument to obtain the desired reliability. Difficulties with sensing element breakage and a deposit forming on the sensing element were encountered. (auth)
- Research Organization:
- National Lead Co. of Ohio, Cincinnati
- NSA Number:
- NSA-13-004626
- OSTI ID:
- 4282343
- Report Number(s):
- NLCO-770
- Country of Publication:
- United States
- Language:
- English