SUPPLEMENT TO THE CALCULATION OF THE COOLING EFFICIENCY OF REACTOR COOLANT CHANNELS (in German)

Journal Article · · Atomkernenergie (West Germany) Merged with Kerntechnik to form Atomkernenerg./Kerntech. Acta Radiol. Changed to Acta Radiol.: Oncol., Radiat. Phys.
OSTI ID:4273645
The cooling efficiency of reactor channels is calculated by three different equations. In the first case the maximum fuel element surface temperature is at channel inlet. The second equation refers to maximum temperature at the outlet, and in the third case the highest surface temperature is between these two extremes. (auth)
Research Organization:
Deutschen Babcock and Wilcox Dampfkesselwerke AG, Oberhausen, Ger.
NSA Number:
NSA-13-005974
OSTI ID:
4273645
Journal Information:
Atomkernenergie (West Germany) Merged with Kerntechnik to form Atomkernenerg./Kerntech. Acta Radiol. Changed to Acta Radiol.: Oncol., Radiat. Phys., Journal Name: Atomkernenergie (West Germany) Merged with Kerntechnik to form Atomkernenerg./Kerntech. Acta Radiol. Changed to Acta Radiol.: Oncol., Radiat. Phys. Vol. Vol: 4; ISSN ATKEA
Country of Publication:
Country unknown/Code not available
Language:
German

Similar Records

TRANSIENT HEAT TRANSFER IN REACTOR COOLANT CHANNELS
Technical Report · Wed Oct 30 23:00:00 EST 1957 · OSTI ID:4317995

TEMPERATURE STRUCTURE IN GAS COOLED REACTOR FUEL ELEMENTS AND COOLANT CHANNEL
Technical Report · Tue May 27 00:00:00 EDT 1958 · OSTI ID:4316685

CALCULATION OF THE OPTIMUM COOLANT STATE IN GAS COOLED REACTORS
Journal Article · Fri Aug 01 00:00:00 EDT 1958 · Atomkern-Energie · OSTI ID:4285808