THE SILVER PHOSPHATE GLASS DOSIMETER (in German)

Journal Article · · Atomkernenergie (West Germany) Merged with Kerntechnik to form Atomkernenerg./Kerntech. Acta Radiol. Changed to Acta Radiol.: Oncol., Radiat. Phys.
OSTI ID:4265897
Thc radiophotoluminescence of silver phosphate glass is a measure for the determination of ionizing radiation. Because of its low zero level, sturdiness, and high sensitivity, silver phosphate glass is well suited for use as personnel radiation exposure monitors allowing the detection of 2 to 3 roentgen (150 kev x rays). Amealing restores the irradiation effects. (auth)
Research Organization:
Univ. of Giessen, Ger.
NSA Number:
NSA-13-013471
OSTI ID:
4265897
Journal Information:
Atomkernenergie (West Germany) Merged with Kerntechnik to form Atomkernenerg./Kerntech. Acta Radiol. Changed to Acta Radiol.: Oncol., Radiat. Phys., Journal Name: Atomkernenergie (West Germany) Merged with Kerntechnik to form Atomkernenerg./Kerntech. Acta Radiol. Changed to Acta Radiol.: Oncol., Radiat. Phys. Vol. Vol: 4; ISSN ATKEA
Country of Publication:
Country unknown/Code not available
Language:
German

Similar Records

PHOSPHATE GLASS DOSIMETER FOR ROUTINE PERSONAL DOSE CONTROL IN NUCLEAR TECHNOLOGY INSTALLATIONS
Journal Article · Sat Jun 01 00:00:00 EDT 1963 · Nukleonik (West Germany) Discontinued with vol. 12 · OSTI ID:4702162

ENERGY DEPENDENCE OF SILVER PHOSPHATE GLASS DOSIMETERS
Journal Article · Tue Dec 31 23:00:00 EST 1957 · Intern. J. Appl. Radiation and Isotopes · OSTI ID:4346739

THE PHOSPHATE GLASS DOSIMETER
Technical Report · Thu May 01 00:00:00 EDT 1958 · OSTI ID:4279642