Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

DETERMINATION OF COMBINED NITROGEN IN TITANIUM METALS

Technical Report ·
OSTI ID:4263489
The metal is dissolved in hot 6 N sulfuric acid and hydrogen peroxide. Ammonia separated by distillation from alkaline solution is determined absorptiometrically using either sodium phenate/sodium hypochlorite for samples containing 5 to 90 ppm combined nitrogen or Nessler's reagent for samples containing 90 ppm to 1.0% combined nitrogen The method has been used for pure powder, sponge, or wrought titanium metal containing 5 ppm to 1.0% combined nitrogen At the 10 and 90 ppm levels results show a negative bias of about 5% with a coefficient of variation of plus or minus 4%. At the 500 ppm and 0.75% levels results are quantitative with a coefficient of variation of about plus or minus 3%. (auth)
Research Organization:
United Kingdom Atomic Energy Authority. Industrial Group. Springfields Works, Springfields, Lancs, England
NSA Number:
NSA-13-017786
OSTI ID:
4263489
Report Number(s):
IGO-AM/S-20
Country of Publication:
Country unknown/Code not available
Language:
English