MICRO COUNTER TUBES FOR BETA-GAMMA MEASUREMENTS
Journal Article
·
· Intern. J. Appl. Radiation and Isotopes
Reta-gamma sensitive micro counter tubes of the Maze type were developed for radioisotope tracer work. The tubes can be sterilized and used in humans for medical diagnosis by radioisotope uptake and for biological research. Flexible lead wires are hermetlcally sealed to the metal-encased glass tubes. Volumes range from 2 mm/sup 3/ to 850 mm/sup 3/, and wall thicknesses range from 0.4 Mev to 0.2 Mev. Thinner windows have been made in some types. Life is >10/sup 7/ counts, with heliuni filling. Practical beta dotection sensitivity ls 0.001 to 0.01 mu at 1.0 cm distance in air. Similar tubes l.0 mm o.d., 6 mm to 30 min long have been made for inter- changeable use in needle-type probes Techniques of construction and typical beta response characteristics to Sr-Y/ sup 90/, Co/sup 60/, Y/sup 90/, and Ra g rays are given. 3 figures. (auth)
- Research Organization:
- Western Radiation Lab., Los Angeles
- NSA Number:
- NSA-13-004858
- OSTI ID:
- 4258515
- Journal Information:
- Intern. J. Appl. Radiation and Isotopes, Journal Name: Intern. J. Appl. Radiation and Isotopes Vol. Vol: 4
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
TECHNIQUES OF ENDO- AND PLESIOCURIETHERAPY WITH ARTIFICIAL RADIOACTIVE ELEMENTS IN OTORHINOLARYNGOLOGY
BETA ACTIVITY DETERMINATION OF LIQUID WASTES
Calibration of a liquid scintillation counter for alpha, beta and Cerenkov counting
Journal Article
·
Fri Jun 01 00:00:00 EDT 1962
· Annales d'Oto-Laryngologie (France) Superseded by Ann. Oto- Laryngol. Chir. Cervico-Faciale
·
OSTI ID:4131822
BETA ACTIVITY DETERMINATION OF LIQUID WASTES
Journal Article
·
Thu Dec 31 23:00:00 EST 1959
· Jaderna energie
·
OSTI ID:4133379
Calibration of a liquid scintillation counter for alpha, beta and Cerenkov counting
Technical Report
·
Mon Jul 01 00:00:00 EDT 1996
·
OSTI ID:366466
Related Subjects
ABSORPTION
BETA DETECTION
BETA PARTICLES
BIBLIOGRAPHY
COBALT 60
CONFIGURATION
COUNTERS
DIAGNOSIS
ENERGY RANGE
GAMMA DETECTION
GAMMA RADIATION
GAMMA SOURCES
GLASS
HELIUM
INSTRUMENTS
LEAD
MAN
OPERATION
PHYSICS AND MATHEMATICS
RADIATION DOSES
RADIOISOTOPES
RADIUM
SENSITIVITY
STERILIZATION
STRONTIUM 90
THICKNESS
TRACER TECHNIQUES
TUBES
USES
VOLUME
WINDOWS
WIRES
YTTRIUM 90
BETA DETECTION
BETA PARTICLES
BIBLIOGRAPHY
COBALT 60
CONFIGURATION
COUNTERS
DIAGNOSIS
ENERGY RANGE
GAMMA DETECTION
GAMMA RADIATION
GAMMA SOURCES
GLASS
HELIUM
INSTRUMENTS
LEAD
MAN
OPERATION
PHYSICS AND MATHEMATICS
RADIATION DOSES
RADIOISOTOPES
RADIUM
SENSITIVITY
STERILIZATION
STRONTIUM 90
THICKNESS
TRACER TECHNIQUES
TUBES
USES
VOLUME
WINDOWS
WIRES
YTTRIUM 90