RAPID ANALYSIS OF GAMMA-EMITTERS USING GAMMA-RAY SCINTILLATION SPECTROMETER. II. DETERMINATION OF $sup 137$Cs IN FISSION PRODUCTS
A method for rapid determination of Cs/sup 137/ in fission products was studied. Known quantities of Cs/sup 137/ were added to fission product solution samples. U was extracted with T.B.P. and the solution treated through an anion exchange bed. A gamma-ray scintillation spectrometer was used to compare the real peak height of the 0.66 Mev gamma and the added Cs/sup 137/ quantity. (J.R.D.)
- Research Organization:
- Government Chemical Industrial Research Inst., Tokyo
- Sponsoring Organization:
- USDOE
- NSA Number:
- NSA-13-016036
- OSTI ID:
- 4255177
- Journal Information:
- Bull. Chem. Soc. Japan, Journal Name: Bull. Chem. Soc. Japan Vol. Vol: 32
- Country of Publication:
- Country unknown/Code not available
- Language:
- English