DETERMINATION OF LOW CHLORINE CONCENTRATION IN PLASTICS
Technical Report
·
OSTI ID:4253804
A rapid method is presented for the determination of low chlorine concentrations in plastics. The method is based upon combustion in a Parr oxygen bomb, an ion exchange step to remove interfering cations, and a mercuric perchlorate titration using diphenylcarhazide as the indicator. The precision is of the order of 0.005%. (auth)