HEATING AND COOLING TESTS ON THE ORR HN-1 IN-PILE LOOP MOCKUP

Technical Report ·
DOI:https://doi.org/10.2172/4243546· OSTI ID:4243546
OTS. Heating and cooling tests were made on the ORR HN-1 in-pile loop mockup 0-l-20 to test the operation of the loop when subjected to reactor scrams or setbacks. The loop was fitted with additional heaters to simulate reactor heat. Reactor transients were simulated by manually changing the power at a predetermined rate. It was found that thc loop control system was adequate and that loop temperatures could be maintained within a total change of 5 deg C. (auth)
Research Organization:
Oak Ridge National Lab., Tenn.
DOE Contract Number:
W-7405-ENG-26
NSA Number:
NSA-13-017560
OSTI ID:
4243546
Report Number(s):
CF-58-10-59
Country of Publication:
United States
Language:
English

Similar Records

AN IN-PILE LOOP FOR TESTING CERAMIC FUELS
Technical Report · Fri Jun 30 00:00:00 EDT 1961 · OSTI ID:4005601

TEST OF HEATER AND COOLER CONCEPTS FOR GCR-ORR LOOP, DESIGN 4
Technical Report · Mon Jul 13 00:00:00 EDT 1959 · OSTI ID:4210036

Organic In-Pile Loop NAA-18
Technical Report · Sun Jul 01 00:00:00 EDT 1956 · OSTI ID:4355527