PRESSURE AND TEMPERATURE IN THE EGCR EXPERIMENTAL LOOP CELL IN CASE OF ACCIDENTAL RELEASE OF MAIN REACTOR COOLANT
Technical Report
·
OSTI ID:4238684
The possibility exists that a failure of the EGCR experimental loop piping in the loop equipment cell can induce a failure of the loop piping within the main pressure vessel due to overheating of the experiment and the collapsing pressure exerted by the main coolant gas. Release of the main coolant into the experimental cell would cause the pressure to rise rapidly above the structural design value of 12 psig unless a pressure relief hole were provided. Accordingly, it is intended that each experimental cell be relieved to the containment shell. A study of cell pressure was undertaken on an IBM 704. This analysis showed that rupture discs or blow-out doors providing 4.29 ft/sup 2/ flow area per cell are sufficient to keep the pressure below 12 psig if 4.67-in.- diam. orifices are inserted in the loop piping. (auth)
- Research Organization:
- Oak Ridge National Lab., Tenn.
- NSA Number:
- NSA-14-002202
- OSTI ID:
- 4238684
- Report Number(s):
- CF-59-10-76
- Country of Publication:
- United States
- Language:
- English
Similar Records
CORE LEVITATION IN THE EGCR IN CASE OF MAIN COOLANT PIPE FAILURE
TRANSIENT HYDRODYNAMIC OPERATION OF EGCR MAIN COOLANT SYSTEM
ANALYSIS OF BOILER ROOM PRESSURES FOLLOWING A POTENTIAL RUPTURE OF THE MAIN COOLANT LINE IN A NUCLEAR POWER PLANT
Technical Report
·
Tue Aug 04 00:00:00 EDT 1959
·
OSTI ID:4202774
TRANSIENT HYDRODYNAMIC OPERATION OF EGCR MAIN COOLANT SYSTEM
Technical Report
·
Mon Mar 13 23:00:00 EST 1961
·
OSTI ID:4055285
ANALYSIS OF BOILER ROOM PRESSURES FOLLOWING A POTENTIAL RUPTURE OF THE MAIN COOLANT LINE IN A NUCLEAR POWER PLANT
Technical Report
·
Mon Aug 01 00:00:00 EDT 1960
·
OSTI ID:4834068