Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

INFRARED METHOD FOR DETERMINING SMALL AMOUNTS OF DIPENTAERYTHIRITOL HEXANITRATE IN PETN

Technical Report ·
OSTI ID:4238532
tometry was developed for the determination of small amounts of dipentaerythritol hexanitrate (DPEHN) in pentaerythritol tetranitrate (PETN). The method involved preparing a 15% solution of the sample in methyl cyanide: measuring the absorbance of this solution at the peak of the 8.9-micron band using a 1.0 mm rock salt cell: and instrumental compensation of the cell, solvent, and PETN. The net absorbance was converted to percent DPEHN by the use of a previously established relationship between absorbance and concentration. This relationship had been established with standards. The developed method is applicable to the determination of as low as a few tenths of one percent as well as higher percentages of DPEHN in PETN with a precision of about 0.1%. (auth)
Research Organization:
Picatinny Arsenal. Feltman Research and Enginering Labs., Dover, N.J.
NSA Number:
NSA-14-001504
OSTI ID:
4238532
Report Number(s):
PA-TN-30; DA Project 5A04-10-0
Country of Publication:
Country unknown/Code not available
Language:
English