Gamma Response and Energy Losses in the Absolute Fast Neutron Dosimeter
Journal Article
·
· Health Physics
The gamma response and the associated question of the neutron energy lost under the bias needed to discriminate gamma radiation in the fast neutron dosimeter is considered for the cases where the y-ray dose rate is high (> 1 r/ hr). The particular dosimeter considered is the so-called absolute fast neutron dosimeter which is calibrated by means of an internal alpha -source. Basic data are given for effective energics of 100 kve and 200 kve x-rays and Co/sup 60/ gamma -radiation. For very high gamma -ray intensities (from 10 to l00r/hr) a graphical method of treating the pulse height distribution data is suggested. Thus, for example, a dose rate of 1 mrad/-hr of Po--Be neutrons can easily be determined even when the y-dose rate is as high as 100 r/hr. (auth)
- Research Organization:
- Oak Ridge National Lab., Tenn.
- Sponsoring Organization:
- USDOE
- NSA Number:
- NSA-13-022296
- OSTI ID:
- 4231376
- Journal Information:
- Health Physics, Journal Name: Health Physics Journal Issue: 1 Vol. 2; ISSN 0017-9078
- Publisher:
- Health Physics Society
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
Complex personal dosimeter
SILICON SEMICONDUCTOR NEUTRON DOSIMETER
NEUTRON-INSENSITIVE BETA GAMMA DOSIMETER
Patent
·
Tue Aug 14 00:00:00 EDT 1984
·
OSTI ID:5991635
SILICON SEMICONDUCTOR NEUTRON DOSIMETER
Technical Report
·
Fri Jun 01 00:00:00 EDT 1962
·
OSTI ID:4784247
NEUTRON-INSENSITIVE BETA GAMMA DOSIMETER
Patent
·
Tue Feb 28 23:00:00 EST 1961
·
OSTI ID:4060574