DEVELOPMENT OF A FAST SCRAM INSTRUMENT OF OMR CRITICAL EXPERIMENT
Technical Report
·
OSTI ID:4231207
The instrumentation scheme for the OMR Critical Facility requires a scram circuit that operates within five milliseconds whenever a predetermined power level is reached. An instrument meeting these requirements was built and tested. Its detecting element is a scintillator sensitive to gamma radiation. (W.L.H.)
- Research Organization:
- Atomics International Div., North American Aviation, Inc., Canoga Park, Calif.
- NSA Number:
- NSA-14-003146
- OSTI ID:
- 4231207
- Report Number(s):
- NAA-SR-Memo-2919
- Country of Publication:
- United States
- Language:
- English