Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

LOCATING DEFECTIVE FUEL ELEMENTS IN BORAX IV

Journal Article · · Nuclear Sci. and Eng.
OSTI ID:4224618
During operation of Borax IV, Cs/sup 138/ and Rb/sup 88/ were identified on a building air filter. This definitely proved that fission product gases were being released from the system. Specific experiments at known powers were conducted to separate fission gas samples from the steam. From radiochemical procedures, it was possible to calculate the minimum amount of exposed U/sup 235/. After several unsuccessful attempts to locate the faulty elements, a simple autoclave technique was developed which promptly detected 22 fuel elements with defective cladding among the original 59. (W.D.M.)
Research Organization:
Argonne National Lab., Lemont, Ill.
NSA Number:
NSA-13-017490
OSTI ID:
4224618
Journal Information:
Nuclear Sci. and Eng., Journal Name: Nuclear Sci. and Eng. Vol. Vol: 2, No. 1, Suppl.
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

FISSION-PRODUCT MONITORING IN EBR-I, MARK IV
Technical Report · Tue Dec 31 23:00:00 EST 1963 · OSTI ID:4027855

FUEL DEFECT TEST-BORAX-IV
Technical Report · Thu Oct 01 00:00:00 EDT 1959 · OSTI ID:4238762

BORAX-IV REACTOR: MANUFACTURE OF FUEL AND BLANKET ELEMENTS
Technical Report · Fri Feb 28 23:00:00 EST 1958 · OSTI ID:4349104