CORROSION OF D LOOP
Technical Report
·
OSTI ID:4221688
The effect of aging on the rate of corrosion in D loop, a large type 347 stainless steel circulating water system, was determined. The study of the possible effect of high water purity on the corrosion rate was a secondary objective of the investigation The loop was operated for approximately 700 hrs with degassed system water at 1700 psi pressure, 490 deg F temperature, and a flow of 3200 to 4000 gpm. Corrosion rate was determined by hydrogen evolution (W.D.M.)
- Research Organization:
- Westinghouse Electric Corp. Atomic Power Div., Pittsburgh
- NSA Number:
- NSA-14-000581
- OSTI ID:
- 4221688
- Report Number(s):
- WAPD-CP-715(Del.)
- Country of Publication:
- United States
- Language:
- English