THE DUCTILITY OF BRAZED STAINLESS STEEL JOINTS

Technical Report ·
OSTI ID:4221453
The ductility of Type 310 stainless steel T-joints brazed with GE-62 brazing alloy was measured. The measure of ductility was taken as the plastic axial strain required to crack braze fillets in T-section tensile specimens. At elevated temperatures, the ductility of as-brazed joints approximated that of the stainless steel, but at room temperature the brazed joints had only 0.1 the ductility of the base metal. Annealing for 16 hr at 1800 deg F in air was found to triple the room-temperature ductility of the brazed joint. (auth)
Research Organization:
Battelle Memorial Inst., Columbus, Ohio
DOE Contract Number:
W-7405-ENG-92
NSA Number:
NSA-14-004547
OSTI ID:
4221453
Report Number(s):
BMI-847
Country of Publication:
United States
Language:
English

Similar Records

DIFFERENTIAL THERMAL-EXPANSION EFFECTS ON BRAZED JOINTS
Technical Report · Tue Sep 01 00:00:00 EDT 1953 · OSTI ID:4328562

ELECTROLESS-PLATED BRAZING ALLOYS
Technical Report · Mon Mar 18 23:00:00 EST 1957 · OSTI ID:4189503

DEVELOPMENT OF OXIDATION AND LIQUID SODIUM RESISTANT BRAZING ALLOYS
Technical Report · Fri Sep 13 00:00:00 EDT 1957 · OSTI ID:4313740