TENSILE TESTS ON ZIRCONIUM SAMPLES (in French)

Journal Article · · Mem. sci. rev. met.
OSTI ID:4221374
Tensile tests were made on zirconium cold rolled or rolled at 400 deg C. After rolling the samples were annealed in vacuo between 400 and 800 deg C. The tensile strength and the hardness vary in the same manner and, for small degrees of reduction, increase after annealing at about 500 deg C. The cold-rolled metal has a lower percentage elongation than all other samples. The tensile curve ior metal heavilyrolled at 400 deg C and annealed at 500 deg C shows a plateau at the plastic limit. (tr-auth)
Research Organization:
Originating Research Org. not identified
NSA Number:
NSA-14-003821
OSTI ID:
4221374
Journal Information:
Mem. sci. rev. met., Journal Name: Mem. sci. rev. met. Vol. Vol: 56
Country of Publication:
Country unknown/Code not available
Language:
French